MTConnect Adapter Catalog

Filter the public TAMS inventory by manufacturer, controller family, equipment category, data source, delivery model, and installation support.

Use the Adapter Guide

Browse the public adapter inventory

The server-rendered inventory currently covers 10 public or custom-scoped records across 6 manufacturers, 4 equipment categories, and 4 data-source patterns. Filters narrow the records; they do not replace controller and site qualification.

10 adapters shown. Use filters to match controller family, data source, and delivery constraints.

Adapter Manufacturer Controller family Data source type Delivery options Install support Validation report Notes
ESAB Laser MTConnect Adapter ESAB
OPC UA Laser Systems Laser
OPC UA → MTConnect
SoftwareEdge-Connect
OnsiteRemote
Report published

OPC UA to MTConnect adapter for ESAB laser equipment, scoped to controller data availability and shop connectivity.

OPC UA server versions vary by ESAB control firmware.
OPC UA endpoint
Quote required
FANUC FOCAS MTConnect Adapter FANUC
FANUC i-Series CNC
MTConnect-native
SoftwareEdge-Connect
OnsiteRemoteSelf-service
Not published

Supports FANUC i-Series: 16i, 18i, 21i, 30i, 31i, 0i, PowerMate-i, and others.

Legacy 16i/18i generations require scoped data mappings.
FOCAS API
Quote required
Haas Legacy MTConnect Adapter
Custom adapter · Request quote
Haas
Legacy Haas Controls CNC
MTConnect-native
Software
OnsiteRemote
Not published

Custom-scoped MTConnect adapter for legacy Haas controller generations where data access varies by retrofit and firmware.

Retrofit viability depends on controller firmware and available data channels.
Legacy (RS232) data interface
Custom development
Haas NGC MTConnect Adapter Haas
NextGen Control (NGC) CNC
MTConnect-native
SoftwareEdge-Connect
OnsiteRemoteSelf-service
Not published

Model-Aware® adapter service for Haas NGC controllers with deployment options aligned to plant network requirements.

Haas controller data services
Quote required
Hexagon CMM MTConnect Adapter Hexagon
Hexagon and Renishaw head controllers Metrology
Other
Software
OnsiteRemote
Report published

Metrology-focused MTConnect adapter for scoped Hexagon, Brown & Sharpe, and Leitz CMM integrations using the cataloged controller interfaces.

Hexagon FDCBrown & Sharp Leitz Protocol
Quote required
PLC Signal MTConnect Adapter LabJack
PLC / Discrete I/O PLC
PLC → MTConnect
SoftwareEdge-Connect
OnsiteRemote
Not published

PLC-to-MTConnect adapter that normalizes discrete and analog signals into MTConnect streams when PLC access is available.

Signal coverage depends on PLC configuration, I/O availability, and wiring access.
LabJack I/OModbus TCP
Quote required
Siemens Powerline MTConnect Adapter Siemens
Powerline CNC
MTConnect-native
SoftwareEdge-Connect
OnsiteRemoteSelf-service
Not published

Model-Aware® MTConnect adapter for Siemens Powerline controller families, tuned to controller options and network constraints.

Coverage varies by SINUMERIK 810D/840D powerline generation and option packages.
NCK data interfacePLC data interface
Quote required
Siemens SIMATIC S7 MTConnect Adapter Siemens
SIMATIC S7 CNC
MTConnect-native
SoftwareEdge-Connect
OnsiteRemoteSelf-service
Not published

Model-Aware® MTConnect adapter for Siemens SIMATIC S7 controller families, tuned to controller options and network constraints.

Coverage varies by SIMATIC S7 generation and option packages.
SIMATIC data interface
Quote required
Siemens SINUMERIK ONE MTConnect Adapter Siemens
SINUMERIK ONE CNC
MTConnect-native
SoftwareEdge-Connect
OnsiteRemoteSelf-service
Not published

Model-Aware® MTConnect adapter for Siemens SINUMERIK ONE controller families, tuned to controller options and network constraints.

Coverage varies by SINUMERIK ONE generation and option packages.
OPC UA endpoint
Quote required
Siemens Solution Line MTConnect Adapter Siemens
Solution Line CNC
MTConnect-native
SoftwareEdge-Connect
OnsiteRemoteSelf-service
Not published

Model-Aware® MTConnect adapter for Siemens Solution Line controller families, tuned to controller options and network constraints.

Coverage varies by SINUMERIK 840D solution line generation and option packages.
NCK data interfacePLC data interface
Quote required

How to use the catalog

  1. Match the equipment manufacturer and exact controller family—not only the machine brand.
  2. Confirm the available controller API, protocol, license, firmware, and network path.
  3. Compare software delivery with the Edge-Connect machine integration appliance.
  4. Open the adapter detail record for prerequisites, published coverage, limitations, and any public validation evidence.
  5. Provide controller and equipment details when requesting an Adapter quote.

Equipment not listed?

An absent record does not determine feasibility. TAMS can evaluate the controller interface, available signals, desired MTConnect model, installation constraints, and validation scope before proposing an integration path.

Architecture, delivery, and validation context

A TAMS machine Adapter obtains controller or signal data and supplies normalized observations to an MTConnect Agent. Downstream monitoring, analytics, and workflow tools consume the Agent stream. Shop-Connect monitors separately supplied MTConnect Agents; it is not an Adapter delivery option.

Protected Website Forms

HTTPS, antiforgery validation, input limits, and reCAPTCHA protect public form submissions. Review the safeguards.